• Features
  • Specifications
  • Downloads
  • Enquiry

Product Feature

  • Compact Plastic Casing, Anti-Shock, Ergonomic, Easy of Operation
  • Wide Range of Syringe Brands - 5 ml, 10 ml, 20 ml, 30 ml,  50/60 ml  
  • Automatic Syringe Type Sensing
  • Three kinds of injection modes: Rate mode, Time mode, Body Weight mode
  • Double CPU Operation, makes injection Safe and Reliable
  • Excellent Flow-Rate Accuracy with Precision Stepping Motor
  • Audio and Visual Alarms - Ensure clinician awareness and prompt intervention
  • Intelligent Pressure Monitoring - Precisely detects over running and obstruction
  • Accumulated injection volume recordable when "Bolus"function is ON
  • Flexible, Power Supply - DC/AC & Built-in Lithium Battery
  • Wireless data transmission with Infusion Monitoring System

Syringe Pump – S550i:

Infusion

Syringe Channel – Single channel

Syringe Capacity

5, 10, 20, 30, 50/60 ml syringes

Syringe Selection / Calibration

Pre-Calibrated Syringe setting and type for Standard Brands, Auto-Calibration for other Brands

Operating Mode

Rate Mode, Time Mode, Body Weight Mode

Flow Rate Range

0.1~100 ml/h (0.1 ml/h step) 5 ml syringe, 0.1~200 ml/h (0.1 ml/h step) 10 ml syringe,

 0.1~400 ml/h (0.1 ml/h step) 20 ml syringe, 0.1~600 ml/h (0.1 ml/h step) 30 ml syringe

0.1~1500 ml/h (0.1 ml/h step) 50/60 ml syringe

Bolus

Manual / Preset - Auto bolus     

Flow Rate Accuracy

Accuracy including syringe: within ± 2%, Mechanical accuracy: within ± 1%           

Accumulated Volume

0.1~9999.9ml    

KVO Rate

0.0 - 5.0 ml/hr Adjustable, 0.1 ml/hr as Default                  

Setting of Delivery Limit

0.1~999.9ml       

Occlusion Detection Pressure

‘L’:40 to 60 kPa , 'M' : 61 -90 kPa, ‘H’: 91 -120 kPa

Display

Screen

3.0 inch Colour LCD screen for Individual Syringe Channel             

Information

‘Syringe Rate’, ‘Volume Limit’, ‘Syringe brand and Size’, ‘AC power / Battery Charge Indicator’, ‘Alarm Information’, Pressure level, ‘Real volume’

Safety Features

Acoustic Alarms

‘Occlusion’, ‘Near Empty’, ‘Infused/KVO’, ‘Syringe Empty’, ‘Plunger disengaged’, ‘Flow rate Error’, ‘Low Battery’, ‘Battery Exhausted’, ‘AC power OFF’, ‘Volume over limited’,  ‘System error’, ‘Confirm/back’, 'Auto Pre-set Bolus', ‘Check Syringe Clamp’  

External Visual Alarm

Dual-Redundant, Dual-Colour Visual Alarms       

Interfaces

Ports

Ambulatory port / 12VDC input, Nurse Call, RS232 Data port

Wireless LAN

Optional

Infusion Management

Wireless Integration with Omya FM1000i model (Infusion Management System)

Power

Power Supply

Integrated Power Supply, rated Voltage AC 100~240V, 50~60 Hz, Power Consumption: 25 VA

External Fuse

1.5 A / 250 V (User Replaceable)

Battery

Battery life

Operates for 6-8 hrs from Full Charge (5 ml/hr at 30°C under Normal Conditions)                              

Battery Operation

Advanced Rechargeable Lithium Polymer battery: 7.4 V, 4000 mAh  

Battery Charge

When AC Power is ON, Battery will automatically Recharge (about 4 hrs to 80% charge)

Safety Specification 

Product Classification

According to the MDD order 93/42/EEC Appendix ? Classification Rule 11: class?b                       

Standards

EN / IEC 60601-1 and EN / IEC 60601-2-24 / CE Marking    in Compliance with the 93/42/EEC European Medical Device Directive

Electric Shock Protection/Class/Level

Class II, Equipment type BF, Continuous Operation         

Ingress Protection

IP 44 (Complete protection against ingress of small solid foreign bodies, and Water splashed against the Device from any direction)

Work Operation

Continuous        

Environment             

Operation Conditions

Ambient temperature: + 5 to + 40°C, Atmosphere Pressure: 86 ~106 kPa, Relative humidity: < 80%

Storage Conditions
Ambient temperature: – 20 to +55°C, Atmosphere Pressure: 50 ~106 kPa, Relative humidity: < 95%

 Non-corrosive gas and well-ventilated room     

Physical Properties            

Dimension

260mm (L) x 148.5mm (W) x 134mm (H)

Weight

2.2 kg (with clamp base)